Lesson. 21 Type of Separators

In food industries, the operations of separating raw products including cleaning and grading are performed by the different engineering properties. Various types of separation equipments have been designed and developed on the basis of properties of the products.

The separation equipment can be classified depending upon the following characteristics of the raw materials;

-size, shape, specific gravity and surface roughness

-magnetic properties, aerodynamic properties, colour, electrical properties

-dielectric properties, rheological properties

A classification of separation techniques according to phases (type of mixture) involved are given as;

 Type of mixture

Techniques

Liquid-liquid

Distillation

Extraction

Decantation

Dialysis and electro-dialysis

Parametric pumping

Solid-solid

Screening

Leaching

Floatation

Air classification

Solid-gas

Cyclonic

Air filtration

Scrubbing

Electrostatic precipitation

Solid-liquid

Sedimentation

Centrifugation

Filtration

Membrane separation


 Screening fundamentals

The objective of a screening operation is to separate a feed stream into two fractions, an underflow that is passed through the screen and an overflow that is rejected by the screen. An ideal screen sharply separates the feed in such a way that the smallest particle in the overflow is just larger than the largest particle in the underflow. Such an ideal separation would define a cut diameter, Dpc, representing the point of separation between the fractions. For an ideal operation, a plot of screen opening against cumulative fraction retained would have the shape shown in Fig.b.

image_1

As can be seen, the largest particle of the underflow (U) has the same size as the smallest particle of the overflow (O). In practice, however, the plot would have the shape illustrated in Fig. 3.1c, in which there is an overlap; the underflow has an appreciable amount of particles larger than the desired cut diameter, while the overflow has particles smaller than such desired cut diameter. That is the actual screens don’t yield a sharp separation. It has been observed that with standard testing screen, the overlap is smaller when particles are spherical (or close to a spherical shape) and is larger when particles are needle-like, fibrous or tend to agglomerate. The main problems encountered in screening result from sample stickiness, sieve blockage, and agglomeration. Commercial screens usually give poorer performance than testing screens of the same mesh handling the same feed mixture. All these problems increase exponentially as the screen aperture decreases.

Percentage open area of a mesh

image_2

eq_1

Example 3.1 Calculate the opening size (Aperture) in mm of a 200-mesh screen of Tyler standard screen series with a wire of 0.053 mm diameter. Determine the percentage open area for this mesh size.     

Solution: 


O = (1/200 x 25.4 – 0.053) = 0.074 mm

Generally, in food industries, screens are constructed by perforated sheet metal or woven wire mesh. The opening in perforated metal sheets may be round, oblong or triangular. The opening in wire mesh is square or rectangle.

 

Last modified: Tuesday, 4 March 2014, 5:48 AM