B.Emission Standards
|
- Parameters Concentration mg/Nm3 at (12% CO2 correction)
- Particulate matter 150
- Nitrogen Oxides 450
- HCI 50
- Minimum stack height shall be 30 metres above ground
- Volatile organic compounds in ash shall not be more than 0.01%
Note:
-
Suitably designed pollution control devices should be installed/retrofitted with the incinerator to achieve the above emission limits, if necessary.
-
Wastes to be incinerated shall not be chemically treated with any chlorinated disinfectants.
-
Chlorinated plastics shall not be incinerated.
-
Toxic metals in incineration ash shall be limited within the regulatory quantities as defined under the Hazardous Waste (Management and Handling Rules,) 1989.
-
Only low sulphur fuel like L.D.0dLS.H.S.1Diesel shall be used as fuel in the incinerator.
|
Last modified: Thursday, 3 February 2011, 6:33 AM