Lesson 28 Hydraulic circuit diagrams and troubleshooting

Introduction

Hydraulic systems is consisted of a number of components which work closely  together to get desired performance which may be pressure control, flow control direction control or miscellaneous functions. A family of graphic symbols has been developed to represent fluid power components and systems on schematic drawings. Hydraulic-circuit diagrams are complete drawings of a hydraulic circuit. It includes the description, a sequence of operations, notes, and a components list. Such  diagrams are essentially required by the designers, the machine makers and mechanics to repair it.

Hydraulic Circuit Diagrams

The circuit diagrams are used in hydraulics to show the components along with their interaction. It a useful tool for the manufacturers and assemblers so that they can come to know  how  the components are to be connected. Mechanics or technicians will be helped with it, that  how the system works, what each component does and what is the flow of  the fluid . It helps them in repairing and also in maintenance of the system. There are various types of hydraulic circuit diagrams which are as follows-

Block Diagram

This type of  diagram indicates  the various components and the lines between the blocks, which indicate connections and/or interactions.

Cutaway Diagram

This type of  diagram indicates the internal construction of the components along with the flow paths. This diagram uses colors, shades, or various patterns in the lines thus it can depict the flow and pressure conditions.

 Pictorial Diagram

This type of  diagram indicates a circuit piping arrangement. The components are usually having similarity  of their actual shapes and sizes.

Graphical Diagram

This type of  diagram indicates  is usually preferred for design and troubleshooting. It uses simple geometric symbols for various components and their controls and connections.

Troubleshooting in hydraulic system

Troubleshooting procedure is required to be performed in a proper manner so that no component is being changed illogically. Hence systematic approach for correcting a hydraulic problem is  a must in the hydraulic circuits. Before starting any troubleshooting operations get informed about the problem. Make out the possible  causes and their suitable remedies of different hydraulic problems occurred during hydraulic system operation. Take care to check that the proper drawings and diagrams are always available of the system or circuit .A convenient table is given for probable cause and suitable remedies-

Fault

Probable causes

Remedies

 

 

Noisy Pump

Hydraulic pump may have  cavitations  and taking air into the system.

Remove cavitations

 

Low fluidl level

 

Fill fluid

To heavy of flud

Use light fluid

Cold fluid

Raise temperature

Suction filter clogged

Clean it

Fluid does not come

Fluid level in the reservoir is low.

 Add the recommended fluid

 

Fluid  inlet hose  or inlet filter is clogged

Clean the filter

Air leak in the inlet line prevents priming

Repair the leaks

The  viscosity of fluid  is too high

Use a lighter oil viscosity

Pump has dirt in it

Clean the pump

 

Overheating of fluid

Contaminants present  in relief valve

 

Viscosity is low

 

fan not running

 

Dirty oil

 

Low fluid level

 

Excessive pump wear

 

Low pressure in the system

Air in the fluid e                                                             

Fill the tank nearly full or recommended level
 

Pressure relief valve  set too low

Reset valve

Defective or worn out pump /actuator

Repair or replace pump / actuator

Pressure relief valve not properly seated

Rectified, adjust the relief valve.

Leak in the hydraulic line

Tighten leaky  connections.

 Foaming of fluid or  air in the fluid

Air leak in hydraulic pump suction side

Tighten leaky connection

fluid level low

Fill fluid

Wrong fluid put in tank

Use proper fluid

Pump shaft seals or access plates could be drawing air into the system

Check for leakage

Excessive Wear

Viscosity of fluid  is too low .

 Use appropriate recommended fluid

High pressure occurs above the maximum pump rating

Check the relief

Misaligned in the drive or belt drive is tight

 Check the parts and rectify the problem.

Air recirculation is causing a chatter in the system

Remove the air from the system

Abrasive matter in the hydraulic oil is being circulated

Put a proper filter to check dust particles

Control valve sticky or working hard

Misalignment in control valve

Align it

Valve is broken

Repair or replace it

Last modified: Thursday, 27 March 2014, 5:23 AM