Procedure

Procedure

  • Weigh accurately 10g of the minced sample.
  • Homogenise with a mixture of 20ml of chloroform and 10ml of methanol.
  • Add 10ml of chloroform to the above mixture and blend for 30 seconds.
  • Add 10ml of distilled water and filter the homogenate through Whatman No.1 filter paper.
  • Transfer the filtrate into a separating funnel and allow to separate
  • Separate the chloroform layer into a previously weighed beaker.
  • Evaporate over a water bath to remove chloroform from the beaker.
  • Dry the beaker in a hot air oven at 100ยบC for 30 minutes and weigh.
Last modified: Monday, 19 March 2012, 6:20 AM