Procedure
|
-
Cut a well pattern as given in the template. The distance between the wells should be 4mm. Remove agarose from the well using the needle and place them on the electrophoresis tank.
-
Fill the buffer tanks with barbitone or Manthoney's buffer.
-
Link each end of the slide to the electric circuit by filter paper strips pre soaked in barbitone or Manthoney's buffer.
-
Wells towards cathode are filled with antigens (known +ve, known –ve and test antigen) and towards anode are filled with antiserum.
-
Electrophoresis is carried out using a current of 8 milliamperes / slide for 45-60 minutes.
-
Switch off and examine for white lines of precipitation between the pairs of wells. Readings are facilitated by oblique light.
-
Fix the protein by immersing the slide in 10% glacial acetic acid.
-
Stain the slide and observe for the presence of precipitation line.
CIE Test
1= Antiserum 2 = Positive control antigen 3 = Test antigen (positive) 4= Negative control antigen
|