Ethylene oxide gas sterilizer

ETHYLENE OXIDE GAS STERILIZER

  • Used for sterilizing the tubings of filling and sealing machine.
  • After sterilization, the tubings should be allowed for sufficient ventilation to remove the residues of gas.
  • The exposure time for gas sterilization is inversely proportional to the gas concentration under which the equipment is exposed in the sterilizer.
  • Commonly used concentration of ethylene oxide is 900 mg / litre of cubic space for a period of 6 h.
  • All items sterilized with gas must be ventilated adequately before use.
  • A minimum of 72 h at room temperature with adequate ventilation is recommended.
  • Items to be sterilized are tubings of filling and sealing machine, rubber plugs of filling nozzles.