Preliminary storage

  • After primary freezing the straws are plunged into the plastic goblet filled with liquid nitrogen.
  • When the boil–off ceases the goblets are transferred to canister of frozen semen container for storage at – 196 ° C.

Post-freezing examination

  • Post thaw motility of samples is assessed after 24 hours of storage.
  • Samples having less than 50 percent progressive motility (under phase contrast microscope) are discarded.
  • Good sample are transferred to permanent storage containers for preservation.
  • Post thaw motility evaluation - done after 24 hours of preliminary storage.
  • Minimum post thaw motility to accept a semen sample - 50%.